Trane model number tonnage Feb 11, 2025 · Confirm with Trane: While the model number usually gives you the tonnage, it’s a good idea to double-check, especially if the model number doesn’t follow the usual pattern or if the unit has special features. 12,000 BTUs per ton. 5 Tons. Face Area (sq. Divide that number by 12, and you’ll have your AC tonnage. These codes are usually numbers divisible by 6 or 12, representing the unit’s cooling capacity in tons. 7½ Ton General Data High Efficiency Table 17-1 General Data 7 Ton Downflow and Horizontal Units model 1 – 5,6 & 7 refrigerant compressor 4 a – 4 8 – 9 design sequence junction box s = side t = top number of cylinders that unload electrical characteristics c 460/60/3 d 575/60/3 e 200/50/3 trane model m nomenclature chart . How do I decode a Trane model number? How to Decode. I. AC Tonnage = 4. Cooling Capacity (BTHU) 18,000 BTHU May 26, 2023 · Trane Tonnage. 22-1797-16-EN Product Data 4YCY4024 through 4YCY4060 Packaged Convertible Gas/Electric 14 SEER 2 - 5 Ton, 60 - 120 MBTU R-410A Gas Electric Packaged (AC & Furnace) Commercial Up To 10 Ton YSC060G3RMB**000000000000000000000000000 Unit Parts List Add To Favorites Add To Stocking List Product Literature Export Product Detail 27. Proven Trane reliability Trane's legendary reliability is based on over 100 years of designing, testing, installing and maintaining chillers around the world. Use our guide above to decode the Trane model number. A set of letters and numbers will be issued to each section. 1 71. Finding your Trane unit’s model number is crucial for Aug 2, 2021 · The Trane model numbering system is divisible. It also shows you what type of refrigerant the unit uses if it is R-22 or R-410A. 2 69. Divide this number by 12. Tonnage (cfm/ton) H = High Effy Multi-Speed, 1-5 - nom. com For more information contact your local dealer (distributor) Literature Order Number 22-1923-1B-EN File Number 22-1923-1B-EN Supersedes 22-1923-1A-EN Date 07/17 For the layman, model numbers might look strange and weird. 5 Trane YHC102F Rooftop Air Conditioner Pdf User Manuals. 4 65. 5 20 25 12. Finding Heil tonnage by model number is probably the easiest as it is rightly placed in the middle of the model number. title: number. For example, if the Trane model number decoding help - HVAC-Talk cooling operations. Trane 2/4TEE Air Handler: 4 Ton 5 Ton. 12½-25 ton packaged rooftop performance data (gas or electric heat) Standard Efficiency High Efficiency Nominal Size (Tons) 12. Nominal Cooling Ton Size: AHRI Efficiency IEER (STD Cooling Only/ VAV Fan) 27. This chiller provides application versatility, ease of installation, control precision, reliability, energy efficiency, and operational The Trane Voyager model YCD075C4LGBE has a tonnage of 75 tons. Model: TCONT402AN32DA S = Low Effy PSC, 1-5 - nom. 8 VDC Size (Footprint) A = 17. Look for the model number, and then within the model for an even number between 18 and 60. 5 15 17. View online or download Trane YHC102F Rooftop Air Conditioner Owner's Manual Model Number Descriptions - 3 ©2020 Trane 22-1901-1J-EN SAFETY SECTION Important — This document contains a wiring diagram, a parts list, and service information. Mar 12, 2024 · How to Find the Trane Tonnage from Model Number As the model number includes some vital information about your Trane HVAC unit. 4 68 67. TONS. Nominal Cooling Ton Size: AHRI Efficiency IEER (STD Cooling Only/ VAV Fan) This video shows how to tell the age and size of your Trane equipment. Standard Noise Rating number is at 95°F outdoor air. Subcooling 16 SEER HP — 2 ton TEM6A0C36H31 4TWR6024H1000A 4TWX6024H1000A 4A6H6024H1000A 13 Degrees 15 SEER HP — 2 ton TEM6A0B24H21 TEM6A0B30H21 4TWR5024G1000A 4A6H5024G1000A 14 Degrees 15 SEER HP — 3 ton TEM6A0B30H21 TEM6A0C36H31 TEM6A0C42H41 4TWR5036G1000A 4A6H5036G1000A 14 Degrees Table 7. Sound Power Level Sound Power Level MODEL A-Weighted Sound Power Level [dB(A)] Full Octave Sound Power(dB) 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TWR4018G1 73 72 66 64 66 Since Trane has a policy of continuous product improvement, it reserves the right to change design and specifications without notice. ) Tube Size Refrigerant Control Internal check valve Drain Conn. ) H x W x D BAYCLE14A1422A 2/4CXAA018AC3CUA 2/4CXAA024AC3CUA TXA018C4 TXA024C4 TXA030C4 14-1/2" Wide Furnaces 22-1/2 x 14-1/2 x 21-1/2 BAYCLE17A1722A 2/4CXAB025AC3CUA 2/4CXAB031AC3CUA 2/4CXAB036AC3CUA 2/4CXAB042AC3CUA 2/4CXAB048AC3CUA TXA025C4 TXA031C4 We would like to show you a description here but the site won’t allow us. (2) Hover over each grouping to reveal pertinent info for each part of the model number. Here’s a few more examples: Trane - 4TWR3030A1000AA - 2-1/2 tons Dec 2, 2024 · Interpreting the Model Number. 5 - 50 Tons. Usua Cross Reference 8 RSP-PRC062A-EN Model F - Open Drive Compressors Best Better ReSpecT COM # Series 6000 COM # Compressor Model # Capacity (Tons) Shipping Model Nomenclature Refrigerant Type 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Product Family Z = Leadership – Two Stage X = Leadership R = Replacement/Retail M or B = Basic A = Light Commercial Family SEER 3 = 13 6 = 16 0 = 20 4 = 14 8 = 18 5 = 15 9 = 19 Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity the specific model number and serial number printed on the unit nameplate. Accessory Description and Usage Anti-Short Cycle Timer — Solid state timing device that pre-vents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. Model Number Coil Cooling or Heat Pump Used With Furnaces Flush on Both Sides Dimensions (in. Tonnage (cfm/ton) No Descriptor 0 = Air Handler / Coil System Control Type S = Standard - 24 VAC C = CLII 13. Consult online resources or Trane documentation for further decoding assistance. 3 4TTR3024H1 74 47. 0 3/8 Non-Bleed TXV Yes 3/4 NPT See outline drawing PLATE FIN 2 / 20 3. 9 56 50. Tonnage (cfm/ton) M = Mid Effy Multi-Speed, 1-5 - nom. Look for the seventh and eighth digits and treat them as a 2-digit number. Locate the model number on the unit’s data plate. . Jan 14, 2025 · Understanding the Trane model number can help you determine critical specifications for your unit, including the SEER rating and tonnage size. Tonnage (cfm/ton) V = High Effy Variable, 1-5 - nom. System Matched with: Indoor Unit Model No. This is not a 5 ton unit, however the 60 right before the 48 could be confusing as 60,000 BTUs would mean it’s a 5 ton unit. First letter: The model number starts with 4. I remember once being unsure about a unit’s capacity because the model number wasn’t clear about certain features. Lets decode the trane model number from the example above: First letter. are located within the oval/round shaped buttons). The Trane model number nomenclature is broken down into segments. Model Nomenclature RefrigeranthType hh 22 hh 410A TRANE ProducthType hh lith h mp Th=hSplithCooling ProducthFamily hh ariabh eedhhhhhhhhhhhhhhhhhhhhhorhBh=hBasic Zh=hLeadershiph–hTwohStagehhhhhhAh=hLighthCommercial hh eadershiph hhhhhhhhhhhLh=hSidehDischarge hh lacemen S = Low Effy PSC, 1-5 - nom. Easy to install and service. ) Duct Connections PLATE FIN 2 / 20 3. For example a 1 ton system would have 12,000 BTU’s. (Note: Tonnage, Air Flow, kW, etc. These are reflected in the model numbers near the middle and often followed by a letter. 2. But still, every letter in the Trane furnace model number can signify something about the model. Model Nomenclature RefrigerantFType FF 22 FF 410A TRANE ProductFType FF litF F mp TF=FSplitFCooling ProductFFamily FF ariabF eedFFFFFFFFFFFFFFFFFFFFForFBF=FBasic ZF=FLeadershipF–FTwoFStageFFFFFFAF=FLightFCommercial FF eadershipF FFFFFFFFFFFLF=FSideFDischarge FF lacemen Jan 1, 2025 · Calculating Tonnage Using Model Number Data. So if the model number is #4TTX4036A1000AA, take 36 and divide by 12, equaling 3 tons. Identify the seventh and eighth digits and treat them as a two-digit number. 5 B Trane rooftop units offer superior indoor air quality, industry-leading energy efficiency, and hassle-free installation—everything you need for new construction or replacement projects. 7 71. 4TTZ0024A1 4TTZ0036A1 4TTZ0048A1 4TTZ0060A1. That is the BTU rating for the unit. 5 x 21. Statitrac, Tracer Integrated Comfort System, VariTrane, Traq, TOPSS, Frostat, eFlex, eDrive, Tracker, 3-D scroll refer to the Trane Residential and Light Commercial Product Handbook. Feb 4, 2019 · Trane XE1100 old 1996 condenser unit model#: TTN024D100A1 serial#: L3244WDBF I REALL JUST NEED TO KNOW TONNAGE. Jan 10, 2025 · Understanding your Trane air conditioner's model number is crucial for finding replacement parts, troubleshooting issues, and even determining the age of your Sep 18, 2024 · Trane often encodes tonnage within the model number. No. 2 71. For example, in the model “4TTA3042A4000B,” the “42” indicates tonnage. The model number is the only identifier needed when referring to a Trane unit in an HVAC system. Even at 600 sq ft per ton that leaves low end 3 ton, high end 4 ton. AC Tonnage (Capacity) = 7th and 8 digits of Model Number / 12. Examine the number’s digits; the final two often indicate tonnage. 3 62. 7 Trane/American Standard Model Number Description T U Y 080 R 9 V3 V 0 Brand Identifier (400 CFM/Ton) Minor Design Change or Service Digit T = Trane A May 17, 2020 · The capacity in tons of a Trane outdoor unit can be determined by dividing the 7th and 8th digit of the model number by 12. ft. Digit 1 — Unit Type Y = Packaged Gas/Electric Digit 2 — Efficiency S = Standard Efficiency H = High Efficiency Digit 3 — Airflow Configuration D= Downflow H= Horizontal Digit 4, 5, 6 — Nominal Gross Cooling Capacity (MBh) 150 = 12½ Tons, 60Hz 155 = 15 Tons, 50Hz ©2020 Trane RLC-PRC020J-EN Introduction To meet a wide range of applications in the me dium-tonnage, water-cooled market, Trane is proud to recommend the model RTHD helical-rotary liquid chiller. How to Decode Trane Model Number Tonnage? Model numbers begin with a 4. Mar 18, 2019 · You can determine the size in tons of your Trane HVAC system by examining the model number on the data sticker at the side of the a/c condenser (outdoor unit). 10 22-1904-1M-EN Mechanical Specification Options General The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor S = Low Effy PSC, 1-5 - nom. Trane is the only brand we are familiar with that occasionally lists a two-digit number for the thousands of BTU rating that is not divisible by 6 or 12—but close. MODEL. WARNING HAZARDOUS GASES! Standard Noise Rating number is at 95°F outdoor air. Every Trane product derives from this unique heritage: • Trane design simplicity • Trane direct drive, low speed, semi-hermetic compressor with only three moving parts Number/Type 2/ManifoldScroll 2/ManifoldScroll 2/ManifoldScroll 2/ManifoldScroll 2/ManifoldScroll PercentCapacity(Stage1-Stage3) 32/68/100 33/67/100 32/68/100 28/72/100 32/68/100 Sound OutdoorSoundRating(dBA) 86 86 86 86 89 OutdoorCoil Type Microchannel Microchannel Microchannel Microchannel Microchannel Configuration FullFace Trane believes that responsible refrigerant practices • Configure to Order model number structure has Digit4–6—Tonnage 060=5Tons(50Hz) 072=6Tons(60Hz) View online or download Trane YHC067E Installation, Operation And Maintenance Manual, Installation & Operation Manual Model Number Descriptions - 3 to 10 Tons (T Model 4PXCAU24BS3HAA 4PXCBU24BS3HAA 4PXCBU30BS3HAA 4PXCCU30BS3HAA INDOOR COIL -- Type Rows / F. The model number starts with 4. 9 60. The result is the capacity of your Trane air conditioner in tons. You can determine tonnage of equipment based on numbers that can be divided by 6 or 12. Table 3. By decoding the model number, you can easily assess the unit’s efficiency and capacity to match your cooling needs. Dec 8, 2024 · Breaking Down the Trane Air Conditioner Model Number. Sound Power Level MODEL A-Weighted Sound Power Level [dB(A)] Full Octave Sound Power(dB) 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TTR3018H1 72 73. Check out the Trane owner's guides for more information about your air conditioner, furnace, heat pump or other Trane HVAC product. Size (in. Tailor to building’s needs with industry’s widest selection of factory-installed options and accessories. 5 B Apr 27, 2020 · A ton of air conditioning equals 12,000 BTU's so, for example a “24” in the middle of the model number indicates that it is a 2-ton system, a “30” means 2-1/2 tons, and the “42” in the middle of the model number at the top of the page means the system is 3-1/2 tons. trane. 5 64. Tonnage is a measure of BTU’s in 12,000 BTU increments. General Directions: (1) Locate the model number your researching. Basically all manufacturers encode the size or tonnage of their systems into the model number. Decoding any equipment model number by standard means requires lots of valuable time. This model number indicates a standard Trane air conditioner with an 18,000 BTUH cooling capacity, a 32 SEER efficiency rating, and heat pump capability. Please return to service information pack upon completion of work. 0 3/8 Non-Bleed TXV Yes 3/4 NPT See outline It depends on the insulation, exposure, region etc, usually 400 - 600 sqft per ton. On the off chance that you stumble on a Trane unit built before 2001, you’ll be able to tell from the slight change in the serial number, which has a number followed by a letter that indicates year and month. Trane air conditioner model numbers are designed to be informative, encoding essential details about the unit. Tons can be determined by the 3rd and 4th numerical digits in the center of the model number for Trane. 3 - 25 Tons Model Number Digits 1, 2 - Unit Model RT = "Rotary Chiller" Digit 3 - Unit Type A = Air Cooled Digit 4 - Project Sequence C = Sequence C Digits 5, 6 e 7 - Nominal Capacity 140 = 140 Nominal Tons 155 = 155 Nominal Tons 170 = 170 Nominal Tons 185 = 185 Nominal Tons 200 = 200 Nominal Tons 225 = 225 Nominal Tons 250 = 250 Nominal Tons 275 = 275 ©2014 Trane Pub. Use in area with questionable power delivery, commercial applications, long lineset, etc. † Removed design special information which includes DDP fan curves. It requires a 115-volt electrical connection. I’m 99% sure this is a 4 ton Unit and you’ve had 2 technicians look at the wrong number of the model number. AC Tonnage = 54/12. First number – The first place holder in the Trane serial number is denoted by a number indicating the year. 5 20 25 4 tons. ) Standard Noise Rating number is at 95°F outdoor air. 5 ton system would have 30,000 BTU’s. Locating the Model Number. Let’s break down the typical format: Example: **TWM048A900A1** TWM: This prefix usually indicates a Trane air conditioner. 2 51. Trane 6200 Troup Highway Tyler, TX 75707 www. 3 1/2 tons appears to be in the general area, with me not having any more information on the home. Jul 7, 2023 · Follow the step-by-step instructions below to determine the tonnage of your Trane air conditioning unit: Find the model number of your Trane air conditioning unit. To calculate tonnage from Trane model numbers, locate the tonnage code, typically found in the middle of the sequence. pLEASE HELP Trane model number decoding help. Divide this number by 12 to get the capacity of your Trane air conditioner in tons. F ora complete listing of lineset options available from equipment supply stores, refer to the Trane Residential and Light Commercial Product Handbook. Aug 27, 2023 · Follow the steps below to determine the tonnage of your Trane AC unit: Look for the model number of your Trane AC. Each segment will have a number of Jan 13, 2025 · Trane age of unit – here is how to read a Trane serial number: For units made from 2002 to 2009, the first number represents the year: 2 is 2002, 3 is 2003, etc. P. Second letter. This is customer property and is to remain with this unit. 6 22-1916-1J-EN Accessory Description and Usage Anti-Short Cycle Timer — Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. You can almost always find these numbers somewhere in the middle of the model number. 5 B † Updated “Model Number Descriptions,” p. Look for the last two numbers of the first numbers after a cluster of letters at the beginning of the model number. A 2. Comfort delivered with ultra-high efficiency at the lowest installed cost. Jun 7, 2023 · The capacity in tons of a Trane outdoor unit can be determined by dividing the 7th and 8th digit of the model number by 12. 0 58. pdf Packaged Rooftop Air Conditioners Precedent™ 17 Plus — Cooling and Gas/Electric 3 to 5 Tons — 60 Hz September 2021 RT-PRC048Q-EN Product Catalog cooling operations. Outdoor Model No. If you look at the Model#, you can see “48” this means 48,000 BTUs. 27 to include both evaporative condensing and air-cooled digits. Heil tonnage by model number. The next two numbers are the week of the year, so 01 would be the first week in January, and 52 would be the last week in December. Accessory Description and Usage Anti-Short Cycle Timer — Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. bhqfooxw lcoo pqsgz wuvok zqlt rqlov eslpwm lewxxc ahtrn wwpleo