Xsy at1 error 1 manual. Buy Frequency Converter VFD XSY-AT1 Inverter 1.

Kulmking (Solid Perfume) by Atelier Goetia
Xsy at1 error 1 manual View and Download XSY AT Series manual online. ja der er en manual med til den, men den skriver intet om resettet - super logisk:-) Jeg tænker også at det må være en eller anden kombination som er nødvendig. Try another motor. 2KW/4KW Single phase 220v Input and three-phase Output motor speed controller at Aliexpress for . Smarter Shopping, Better Living! 0 XSY-AT1 VFD invertor, so I thought I would group as much information together as possible. Any thoughts or links welcome. Parameterspecification Parameter Parameter specification Parameterrange Default Unit P00 Maximum voltage 0---220. The inverter box was smoking and said ERR on the LCD screen. Oct 13, 2019 · I can’t seem to figure out why the fault won’t go away when I press the reset button. AT Series inverter pdf manual download. Based on 1090 MHz receiving and FLARM transceiving technology, AIR Traffic processes data from 1090 MHz Mode-S transponder replies, 1090 MHz ADS-B broadcasts, and FLARM broadcasts to calculate positions, flight vectors, and threat levels of other air traffic. So what is stored in parameter P076 ? Sep 4, 2024 · Refer to the installation manual of the AT-1 starting on page 51 as well as the user manual from page 16 you will find more information about the update process. With wave filter <br>2. 25 to 1. (June 2024 around $200) Jun 14, 2019 · After a year of service, which by the way was not continuous, the VFD started faulting with several different overload faults. Find more 13, 14191102 and 5 products. Err 1 means ov Mar 12, 2021 · Yep, no explanation as to the parameter mumbo jumbo in the manual. Jul 31, 2018 · Hi, I recently bought a VFD for a 2. It includes information on the quartz movement, running reserve, cycle time, accuracy, temperature ranges, contact ratings, load types, connection capacity, and dimensions. 5kW 3 phase TEC motor for my drill press upgrade: Attachment 29780 The 'manual' which came with it was just a large sheet of paper with lots of information crammed onto it. Sep 19, 2019 · speed input 1 Section speed input 2 Section speed input 3 Original Frequency Main Speed 1 1 1 50 Section speed 1 1 1 0 45 Section speed 2 1 0 1 40 Section speed 3 1 0 0 35 Section speed 4 0 1 1 30 Section speed 5 0 1 0 25 Section speed 6 0 0 1 20 Section speed 7 1 1 1 15 Note: 0 means input Port connect with COM, 1 means disconnect. Safety notes CARDIOVIT AT-1 G2 User guide Symbols and Pictograms 1. Jan 4, 2020 · Wired it as my other XYS-AT1 unit and the same as Routercnc did in his video. My first vfd so I'm stuck here. XCFDP. These updates are available free of charge. For use on XSY-AT1 VFD - Free download as PDF File (. AT1-2200X inverter pdf manual download. After taking everyone’s advise on Mar 26, 2019 · Buenas tardes,tengo un variador chino de 3cv,en concreto Xin Shuang Yuan XSY AT1 modelo AT1 2200X,el caso es que lo configuro a 400 hz y perfecto,el tema del interruptor y potenciometro externo lo tengo controlado,las conexiones tambien,pero lo arranco en vacio sin conectar el teknomotor y le meto el polimetro y me marca 400 voltios,el parametro P00 (maximum voltaje) esta configurado por About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Aug 29, 2020 · Buy Variable Frequency Drive, AT1-1500S 220V 1. After taking everyone’s advise on XSY-AT1-1,5kw Inverter input 1 phase 220vac Output 3phase 220vac 2HP di Tokopedia ∙ Promo Pengguna Baru ∙ Cicilan 0% ∙ Kurir Instan. 5kW AC Motor: Controls - Amazon. Got the 2 page manual, looked at it after I had wired it, no load just the three mains wires. I wish to connect the outputs from the relay to For and DCM which are not labelled on the XSY-AT1. Hi, I have an XSY-AT1 Chinese Unbranded 1. 2KW/4KW Inverter XSY-AT1 ZW-BT1 Frequency Converter Single-Phase Input and 3-220V Output Motor Speed Controller at Aliexpress for . 2KW 3 Phase Variable Frequency Driver VFD Frequenzumrichter Inverter 220V Q3W3 Hergestellt aus hochwertigem Frequenzumrichter, hat eine schöne Haltbarkeit und lange Lebensdauer. com FREE DELIVERY possible on eligible purchases Skip to View and Download Schiller AT-1 instruction manual online. Oct 19, 2023 · The one thing about this site they try to make you download a zip program or similar, probly how they make their money to actually download it on it's own you have to pick the right download link but it is not obvious, I just tend to browse the manual but it's a bit awkward, I have in the past downloaded a manual from them eventually, ended Oct 13, 2019 · I can’t seem to figure out why the fault won’t go away when I press the reset button. AGCB97 H-M Jan 23, 2021 · I have a AT1 but looking at my manual for configuring inputs PTP it gives options 10 and 11 both as keying forward switching. Not exactly comprehensive. So something like the motor current x 1. Manuals and User Guides for XSY AT1. 5hp 6 pole 3 phase motor which was originally wired in star, I have now moved the links to the delta configuration so that I can run it off a variable frequency drive. Monophasé à triphasé, Monophasé à monophasé, Triphasé à triphasé. Jul 17, 2022 · AT1-1500X MANUAL DOWNLOAD LINK AT1-1500X MANUAL READ ONLINE amdo vcd 1000 manual pdf xsy-at1 wiring diagram xsy-at1 error 1 at1 inv… Manuals and User Guides for VEVOR AT1-2200X. 0 2 Reviews ౹ 15 sold. If I turn P72 up it works great at low speeds but then I get too much current at high speeds. Color: 1. 3A. , Pd004 now i set it on 60Hz but i read somewhere that is better to put a higher value (400 was the recommended frequency). Some better than others. Aug 16, 2008 · I have an XSY-AT1 single phase 230v to 3phase 230v inverter on my lathe. 0 220/380 V Posted by u/Live_Cryptographer23 - 1 vote and 1 comment About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Jan 9, 2020 · air avionics AIR Traffic is a state-of-the-art traffic/electronic conspicuity system. - Explanations of the control terminals and their functions for controlling speed, direction, and more. I ended up purchasing two XSY-AT1 VFDs and a spare motor on Ebay. We have 1 VEVOR AT1-2200X manual available for free PDF download: Manual Apr 1, 2021 · In diesem Video zeige ich Dir am Beispiel meines Töpferscheibenprojekts wie ich die Drehzahl eines Drehstrommotors über einen Frequenzumrichter verändern kan About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Buy VFD 1. Worth a search for "AT1 inverter 3 wire control model engineer". Voir et télécharger XSY AT Serie instructions d'opération en ligne. This document provides technical specifications for the AT1 and AT1-R quartz time switches. Sounds like it is running at least. View attachment 402969 View attachment 402970 View attachment 402972 View attachment 402973 The manual is decently sized (177 pages) and provides adequate information. We have 2 air avionics AT-1 manuals available for free PDF download: Installation Manual, Pilot's Manual air avionics AT-1 Installation Manual (116 pages) May 28, 2023 · To give you an idea of the size, here it is next to another 1. The maker model of the VFD is as below. Tutorial di elettronica. Jun 7, 2024 · I went with a XSY-AT1 /AT1-2200S (Ver A03) VFD Inverter. I heard a pop, and my lights in the workshop turned off. I took off the casing and turned the grinder on again from a distance to see if I could see where the smoke was coming from. XSY-AT1 invertor parameters suggest a max of 400 Hz: P00 Maximum voltage 0---220. 75 So to help me out I created my own VFD Inverter VFD 1. I have used a couple of toggle switches an Aug 7, 2024 · Hi, this is the first page of parameters. Free Shipping. 5KW 220V. pdf) or read online for free. May 11, 2018 · Hi, I recently bought a XSY-AT1 VFD (1ph to 3ph) to run my 2. 5KW/2. Power off. 5. 1 Symbols used in this document The safety level is classified according to ISO 3864-2. I assume keying means recieving a momentary start command from a push button. I have put the 123 wires The XSY AT3 is a three-phase to three-phase inverter designed for high performance and low noise operation. 3. INVERTER AT1-2200X XSY-AT1 2,2 KW 2. I assume this is a typo and one should be keying stop. And #2 fault code under voltage protection. Mar 24, 2023 · After a year of service, which by the way was not continuous, the VFD started faulting with several different overload faults. . The whole display just flashes indefinitely, as opposed to the expected single-digit flashing. 2KW 110V AT1) Compartir: Aug 16, 2008 · I have an XSY-AT1 single phase 230v to 3phase 230v inverter on my lathe. If you have input, I would like to see it :) Aaron Very useful, thanks. Output voltage mode: PWM control <br>8. txt) or read online for free. I don't know ALL about it but keep learning! Use it at your own discretion. Has anyone set one of these up to add these functions to this VFD. Oct 16, 2020 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright View and Download Canon AT 1 instructions manual online. 11. FLARM systems, including the AT-1, require periodic software updates to maintain their functionality. The setup process wasn't t Need Help! Dec 31, 2011 · The AT1 will not allow a normally-closed stop button to be used, but it can be set up to work with a normally-open "stop" button. 5 кВт 220В/380В купить в интернет-магазине KING-TOOLS ⭐ 100% оригинал ️ Выгодные цены ️ Инверторы (преобразователи напряжения) ️ с доставкой по Украине ⏩ Заходите XSY-AT1 VFD & 3 Phase Motor Bench Test Review Mini Lathe & Myford. Also for: At1, At2, At3. 5hp knifemaking grinder which is controlled by an XSY-AT1 inverter. 5kW VFD. Jan 15, 2021 · P010 Working frequency source 1 default - P011 Start/stop control source 0 default - P012 Stopping Modes 1 default - P013 Braking time 0,5 default S P014 Braking voltage 20 default V P015 not listed 2 not listed - P016 not listed 1 not listed - P017 Machine number 1 default - P018 Operating arrival 50 default Hz P019 not listed 50 not listed - P020 Inverter / vfd Manual 類 single phase input three phase Inverter / vfd Manual 類 single phase input three phase output 0. Rated current: 12A <br>7. I have an XSY-AT1 and it worked perfectly, but I have reset it on the P77 and since that one it didn't work. The motor is no longer connected but the error continues. 2KW/4KW Single Phase 220v Input & Three-Phase Output Motor Speed Controller China Sourcing Agent service to protect the product quality and payment security. AT 1 film camera pdf manual download. 2KW 220V AC 12ANie będę pokazywał wszystkich programów . Open up the vfd (power removed, give 24h for any caps to discharge). 75kw / 1hp model XSY-AT1 watch here — Display the value with button [6]. Boss pwd po ba sa 3/4hp 60hz na water pump ang XSY-AT1 na vfd Xsy at1 manual pdf Rating: 4. For those not familiar with this model VFD - they are commonly sold on ebay as a HY knock off but there are If there is any problem which isn’t listed in this manual, please contact the local dealer or Isacon’s custom service center. Manuals and User Guides for air avionics AT-1. 5kW 8A VFD Inverter Frequency Converter PWM Control for 3-Phase 1. It was working fantastic until today. View attachment 402971 Aug 7, 2018 · XSY-AT1 Model: AT1-2200X Ver: A03 I'd like it to start stop, and if possible determine the spindle speed from the BOB using Mach3 gcode. Err 1 means ov Buy Frequency Converter VFD XSY-AT1 Inverter 1. So what is stored in parameter P076 ? XSY-AT1 VFD Frequency Converter 3 Phases 220V Output Variable Frequency Drive Industrial Motor Control Device. who can give me the exact sequences of settings. May 2, 2023 · Podłączenie falownika XSY-AT1 2,2 kW do silnika 3 Fazowego. 11 Symbols and Pictograms 1. 2KW 220V-BT1) (4KW 220V (blanco) : Todo lo demás. To its defense, i was running "thread cutting rpm". XSY-AT1 VFD - Free download as PDF File (. Beli XSY-AT1-1,5kw Inverter input 1 phase 220vac Output 3phase 220vac 2HP di Aufa dinamika elektrik. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Купил шпиндель на 1. This i the simple explanation on how to wire the cheap Chinese VFD AT1 (single phase to 3-phase) so that it can be controller externally with a 10K potentiom About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Jul 6, 2024 · J'ai un problème sur mon variateur xsy-at1 Lorsque je tourne le potentiomètre ma fréquence varie seulement de 22,5hz à 42,5hz soit une variation de 20hz Mes paramètres sont les suivants: P01: 50hz P03: 25hz P05: 0hz P06: 80hz P07:20hz P26:50hz J'ai le même probléme en utilisant le potentiomètre déporté ou en utilisant le Oct 31, 2023 · Buy Inverter 1. 5kw 220v single to 220v three-phase VFd. Oct 31, 2018 · Je vous présence un petit test du variateur de fréquence XSY-AT1 acheté sur Amazon environ 70 € VFD XSY-AT1-2200S: Package: Description: 2. Inverter XSY AT1 input 220V Single Phase to 220V 3 Phase, sedangkan inverte Buy Frequency Converter VFD XSY-AT1 Inverter 1. My problem is trying to work out the correct connections on the VFD. 1. - Descriptions of the main circuit terminals and their functions. 1KW 3 phase motor- ive wired it all up and everything runs fine as is. L'inverter su Amazon: htt Now taking a better inspection Pd003 (according the manual MAIN FREQUENCY) remains on 50Hz, cannot be changed to a higher freq im assuming that this is the input frequency. 2KW Frequency Inverter XSY-AT1 3P 220V Output Frequency Converter Variable Frequency Drive (Color : 2. 2kw air spindle as part of a new machine build. Thanks tarawa. Ive just bought a new 1. I completely rewired the machine then started on the long journey of programming the VFD. Sign In Upload. For a motor I used a 220v / 3 phase / 2HP available from Amazon or Ebay. Xin Shuang Yuan Co Ltd XSY-AT1 Model: AT1-2200X Ver: A03 I'd like it to start stop, and if possible determine the spindle speed from the BOB using Mach3 gcode. SETPOINT (display and modification of desired temperature value) — Press button [6] for at least half second to display the setpoint value. Sep 24, 2022 · I have a XSY-AT1 VFD on a 2 HP Bridgeport mill. The motor is probably fine but that will rule it out. 0 220/380 V Hello, I am using a VEVOR model AT1-220X inverter for use with a VEVOR JST-JGF-2. XSY-AT1 [ 1 phase input, 3 phase output ] GREEN = setting up to motor and drive parameters (needed to get the motor operating) BLUE = optional tuning parameters -not required initially but allow some customisation Jun 23, 2019 · Test Inverter XSY-AT1 220v 1,5kw Apr 22, 2016 · Best programming instructions/manual for XSY-AT1 VFD. 1KW 110V AT1) : Amazon. 2KW/4KW Single Phase 220v Input & Three-Phase Output Motor Speed Controller, ECVV providesFrequency Converter VFD XSY-AT1 Inverter 1. 5 x 1000 = motor current with 150% overload in mA. Performance: Broken wire protection, adjustable acceleration, water pump control, travel switch, 8-speed control, no streak MANGAO Inversor 1. Title: AT1-2200X说明书(转曲) Created Date: 9/3/2019 10:15:47 AM This document provides information about an inverter, including: - Details on 4 types of inverters for different input/output phase configurations. 2KW Inversor de frecuencia XSY-AT1 3P 220V Convertidor de frecuencia de salida Variable Unidad de frecuencia (color : 2. At the time of this post, (June 2024) around $70 on Amazon and Ebay. pdf), Text File (. Its motor is a 220V x 750w 50Hz that is single-phase and the house current is 220v I tried sifting through the network but it didn't bring any results . We have 1 XSY AT1 manual available for free PDF download: Manual XSY AT1 Manual (22 pages) Oct 14, 2019 · I have a XSY-AT1 inverter connected to my lathe motor and yesterday it stopped working with the displayed fault of "ERR 1". - Wiring diagrams for the 3 main input/output phase configurations Nov 12, 2015 · I set up one of the P50-55 wires to setting 19 which is "emergency stop" in the manual. 5kW 3 phase TEC motor for my drill press upgrade: 29780 The 'manual' which came with it was just a large sheet of paper with lots of information crammed onto it. 24607 Come usare un Inverter XSY-AT1 per motore trifase - Video 247 del corso Elettronica per Maker in 100 video. and I have to configure it with my DamatoMacchine lathe. OK. I purchased this XSY-AT1 inverter . I shut down the circuit breaker and recycled. частотный China Frequency Converter VFD XSY-AT1 Inverter 1. Mar 6, 2019 · Hi, I have an XSY-AT1 Chinese Unbranded 1. 5кВт с воздушным охлаждением для для фрезерного ЧПУ станка! А т. AT Serie onduleurs téléchargement de manuel pdf Aussi pour: At1, At2, At3. XSY-AT1 VFD MANUAL DOWNLOAD LINK XSY-AT1 VFD MANUAL READ ONLINE chinese vfd manualxsy-at1 factory reset at1-2200x manual enc vfd manual pdf xsy… Dec 6, 2023 · You may not post new threads; You may not post replies; You may not post attachments; You may not edit your posts Feb 18, 2021 · Can anyone help me? I am trying to connect my XSY-AT1 to a Gecko G540 using a relay to control the motor with MACH3. (Ve I was using my 1. Title: AT1-2200X说明书(转曲) Created Date: 9/3/2019 10:15:47 AM See how easy it is to connect, use and program the excellent (XSY-AT1)variable frequency drive inverter from Banggood to a new 3 phase 1HP motor. Feb 22, 2024 · 1 PC Inverter XSY-AT1 AT1-1500X 1. Manual do inversor AT1 4000 x. 1; 2; First Prev 2 of 2 Go to page. I found this forum searching for setup for a XSY-AT1 VFD, mine just arrived today - started it up with factory settings -Fault Err 1: Altered P24 from 3 to 6 - according to your setup - started up perfectly. Attachment 29781 I have configured mine to work with a 1. 6A or 2. 29781 I have configured mine to work with a 1. Nov 6, 2024 · Hopefully this information will enlighten you xys at1 4. Jan 10, 2019 · I have an XSY AT1 VFD and a Teco 3 phase 1hp motor. Es hat eine gute Leistung und eine starke Funktion. com. Scribd es red social de lectura y publicación más importante del mundo. The panel shows 19103 or 21301. Частотный преобразователь, Однофазный Частотник Cool Classic XSY-AT1 1. 75 HP perhaps. Jan 23, 2021 · After a year of service, which by the way was not continuous, the VFD started faulting with several different overload faults. Apr 4, 2021 · XSY-AT1 VFD invertor, so I thought I would group as much information together as possible. The time switches have a 24 hour cycle, accuracy of ±1 second per day, and can handle resistive loads up to 16A and inductive XSY AT1 Parameters - Free download as PDF File (. Disconnect motor and check resistance of the windings. Inverter 1. Phone : 057687161633(10 Line)-Department of Technology Amazon. 2KW XSY-AT1 VFD a while back and now looking to use it on my milling machine. This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to both Part 15 of the FCC (Federal Communications Commission) Rules and the radio interference regulations of the Canadian Department of Communications. I had it going great up until a few days ago, where I am now unable to adjust any of the program settings. 09-2 Perske spindle motor, model V 30, type VS 31, rectangular motor, 1. Apr 22, 2016 · Anyone have a link to a readable manual? It would also be helpful to me to understand what some of the parameters mean (those that are not self explanatory). com: Inversor 1. you cant say they are hidden. 8A). The motor is wired for 240 V. 2KW Frequency Inverter XSY-AT1 3P 220V Output After you pay for it, I will send the English manual to your e-mail when I shipBest programming instructions/manual for XSY-AT1 VFD · Go to page · AGCB97 · Ulma Doctor. 8 / 5 (17328 votes) Downloads: 103823 >>>CLICK HERE TO DOWNLOAD<<< So now i' m replacing it with a little banggood vfd, so i can finally fini… H100 VFD Inverter Manual - Free download as PDF File (. Go. 2 kw 220V 1PHASE 3PHASE 3 phase 1p di Tokopedia ∙ Promo Pengguna Baru ∙ Cicilan 0% ∙ Kurir Instan. The nature of the DC power supply: voltage type <br>6. We have 1 XSY AT Series Converter Inverter manual available for free PDF download: Manual XSY AT1 ; XSY AT2 ; XSY AT3 Oct 13, 2019 · Hej Jens og tak for svar. Power supply voltage: low voltage <br>5. Scribd is the world's largest social reading and publishing site. — While keeping button [6] pressed, use button [9]. 2KW Frequency Inverter XSY-AT1 3P 220V Output Frequency Converter Variable Frequency Drive (Color : 1. The following overview shows the safety symbols and pictograms used in this user guide. 5KW /2. For some reason it just cuts power and the motor coasts down at the limits of physics rather than actively braking. Doing a project I decided to turn up the speed using the knob on the control padNothing. 35 hp / 1 kW, 30,000 RPM, 500 Hz, 220 V. Problem Error 2 terjadi biasanya akibat dari kapasitor besar dengan nilai 6800uF/400V yang sudah rusak, tetapi bisa juga terjadi akibat dari adanya program y Nov 1, 2019 · Hi I ran a 240 circuit to my lathe 13x40 Enco it's got 3 phase 1 1/2 horse motor with vfd display comes on all defaults are correct except P11 stays on blinking 2. in advance thanks. Download Table of Contents Contents. ca: Electronics Feb 25, 2020 · I bought a 2. Jednofazowy przemiennik częstotliwości 2. I'm just trying to get the basics set up, 400khz and min freq 120khz etc. 0/380. This was properly messing with my head until I found a discussion on the Model Engineer forum that cleared things up. 11 1. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Jul 29, 2020 · It is driven by a 0. If you have programmed one of these, your notes would be valuable to me. 2kw spindle. 5KW 220V(white) Oct 21, 2019 · xsy-at1 bedienungsanleitung deutsch xsy at1 kaufen xsy-at1 bedienungsanleitung xsy at3 manual xsy-at1 err 1inverter xsy-at1 frequenzumrichter xsy-at1 Items 1 - 32 of 32 If you want to buy cheap variable frequency drive xsy at1, choose variable frequency drive xsy at1 from banggood. com FREE DELIVERY possible on eligible purchases Jul 14, 2021 · VS 31. Feb 20, 2020 · OK. It would appear that you may need to adjust P76 which appears to be the motor current with overload in mA. P0=220V P1=400Hz P2=110V P3=200Hz Note that this is where I suspect you are going wrong. 2KW-ER20 spindle motor (220V, 400Hz, 7. 4kw inverter 240v mains to 240v 3 phase permanent magnet synchronous motor 60hz 16755 rpm I'm trying to understand the instructions for parameters with a lot of difficulties Here is a quick video on wiring a remote Start/Stop switch and a remote Forward/Reverse switch to a Chinese XSY-AT1 / AT1-2200S Variable Frequency Drive. After taking everyone’s advise on 您在查找xsy-at1单相变频器说明书吗?抖音综合搜索帮你找到更多相关视频、图文、直播内容,支持在线观看。更有海量高清视频、相关直播、用户,满足您的在线观看需求。 Apr 19, 2011 · This is my latest and greatest rendition of the XSY-AT1 manual interpretation. Video ini sebagai pertimbangan ketika menentukan penggunaan inverter Single Phase. if you have specific questions, go ahead and shoot! Thanks Mike. Nov 13, 2019 · Hi, I recently bought a XSY-AT1 VFD (1ph to 3ph) to run my 2. The manual says different than the board?! Routercnc mentions in his video a similar issue with another inverter. Its not clear to me from the wiring diagrams of the VFD which control wiring connections to connect to the BOB. I have recently purchased a cheap Chinese XSY-AT1 variable frequency drive and it runs the saw perfectly. 2KW 220V-BT1) (4KW 220V(White): Everything Else - Amazon. I'd like it to start stop, and if possible also set the speed from Mach3 gcode. I went through all of the program settings, and only P9 is able to be changed. gives ERR1 someone could help me? 11-09-2019 #2. Jun 4, 2019 · I have a XSY-AT1 VFD on a 2 HP Bridgeport mill. with manuals. I have been trying to get the torque boost to work right over a range os speeds. Feb 18, 2022 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Apr 8, 2018 · Hi, I have an XSY-AT1 inverter 3pH, i'm setting it up for the spindle below and just have a bit of a problem with the terminology in my manual, which differs from much of the documentation I see about the HuanYang, which I was using as a reference. This inverter is supposed to be good for 12 A, and the motor is either 4. SAFETY ALERT for XSY-AT1 VFD inverter users - and perhaps other chinese units smithy I suspect this may have similar specs 180 volt 1. I turned the lathe off and then it would not start. 1: operating frequency 2: Revolution (Drehzahl) 3: Current (Strom) 4: Temperature 5: Time 0 4 P77 Parameter reset (Werkseinstellungen) 0-65535 (It is the reset when 54321) 0 P78 Main current overload (Überlaststrom) 0-65535 3000 mA 3,36A x 1,15 x 1000= 3864 mA Frequenzumrichter XSY-AT1 Model: AT1-1500X Nennspannung: AC230V (einzelne Phase) Jun 14, 2019 · Thanks tarawa. Rated voltage: single-phase AC 220V <br>3. Thread starter AGCB97; Start date Nov 3, 2021; Prev. Control method: V/F open loop <br>4. May 28, 2023 · It seems like there are many 'versions' of manuals for the AT1 inverters. Feb 14, 2023 · I've made a panel so I can control my VFD remotely, simple set up for run/stop, forward/reverse and variable speed. This device is ideal for driving mini AC motors, offering multiple speed settings, and featuring an operation panel with buttons for programming and control. -10-Chapter2Parameterspecification 1. According to the manual this is "Short Circuit/Current overload/Power Module protection". Manual Inversor - AT1 4000X - Free download as PDF File (. к. View and Download VEVOR AT1-2200X manual online. View and Download XSY AT Series manual online. I have got it wired up and wire 1 is in U, wire 2 is in V and wire 3 is in W. Add to my manuals. See attached photo. Its not clear to me from the wiring diagrams of the VFD which control wiring connections to connect to the BOB for these control. sqtq iwvduulj rwsa ughgxga bcrcf yfobe hyrp bcr lmwnnoswd ycyzrk